CC640 Digital Camera

Logger Connection

COMCBL1-L

19504

17988

Camera Connection

C1947

FIGURE 6. Camera RS-232 to RS-232 Port Connection

It’s also possible to use RS-232 protocol via the control ports of CR800,
CR1000 and CR3000 loggers. The connection is listed below.

TABLE 4. Camera RS-232 to Datalogger

Com Port Connection

RS-232 connection 9 pin to pigtails
COMCBL1-L

Pigtails to logger control ports

YL G
WH

Even # control port

BN

Odd # control port

Camera

data cable

logger control ports

C1947-----Æ COMCBL1-----Æ

If the recommended cable is used, the RS-232 can be used at distances up to 30
Meters (98.1 feet). Longer lengths or different cables may require that the
BAUD rate be set slower than the default 115200 BAUD.

The RS-232 port is used in conjunction with the Device Configuration software
to change settings in the camera such as the PakBus addresses. Figure 7
illustrates the connections required for interfacing to a computer. A straight