2 communication, 1 communication disabled, 2 cs i/o communication – Campbell Scientific CC640 Digital Camera User Manual

Page 31: 3 rs-232 communication

Advertising
background image

CC640 Digital Camera

10.2 Communication

Communication can enable remote retrieval and/or storage of images to
external devices such as compatible Campbell Scientific dataloggers. The
PakBus protocol is used to transfer the images.

10.2.1 Communication Disabled

When a camera is not connected to other devices for communication then it is
important to:

• Set the parameter PakBus Port to None

10.2.2 CS I/O Communication

The camera can download images to a compatible Campbell Scientific
datalogger via the CS I/O port. The following items are required for CS I/O
PakBus communication:

• Set the parameter PakBus Port to CS I/O

• Set the parameter PakBus Address to a unique value in the PakBus

network.

• Set the parameter PakBus Destination Address to the datalogger that is

intended to store the images.

• Insure that the parameter CS I/O CSDC ADDRESS of the camera is

unique among the peripherals that are connected to the dataloggers’ CS
I/O port.

• Connect the camera CS I/O port to the datalogger using the supplied

ribbon cable adapter.

• Insure that the datalogger CS I/O BAUD rate is set to 76.8 KB or less

Refer to 4.4

for connections required when using the CS I/O port.

The camera must always have +12Volts power connected to it
when connected to the CS I/O port of a datalogger. Failing to
apply power to the camera will prevent other devices from
communicating with the datalogger.

NOTE

10.2.3 RS-232 Communication

The camera can download images via its RS-232 port using the PakBus
protocol. The following items are required for RS-232 PakBus
communication:

• Set the parameter PakBus Port to RS-232

• Set the parameter PakBus Address to a unique value in the PakBus

network.

25

Advertising