Installation, 1 enclosures – Campbell Scientific CC640 Digital Camera User Manual

Page 42

Advertising
background image

CC640 Digital Camera

FIGURE 15. Task using Add After to Collect Images

after Scheduled Call

Note that it is necessary to specify the directory in which the files are located
for the CR800, CR850, CR1000, and CR3000. In our example the USR: drive
is selected. Another option is the CRD: drive if the CompactFlash module is
used with the CR1000 or CR3000.

15. Installation

The camera must be installed in an environmentally sealed enclosure that offers
protection from moisture or high humidity. It is also recommended that
desiccant be installed in the camera enclosure to absorb excess humidity.
Failure to install or replace the desiccant as required may cause malfunctions or
damage the camera.

15.1 Enclosures

The 18543 CC640 Camera Enclosure completely encloses the camera and has
a window through which images are acquired (see Figures 16 through 18). The
26140 Heater Kit is offered to prevent the enclosure’s window from frosting
over (see Appendix B). The enclosure attaches to a CM202, CM204, or
CM206 crossarm via the 18549 Mounting Kit (see Section 15.3).

36