3 start delay using pulse input, Start delay using pulse input – Campbell Scientific CVS4200 / BVS4300 Stationary Samplers User Manual
Page 48
CVS4200 / BVS4300 Stationary Samplers
The controller has now been given a new 
value for START DELAY. The new values 
reside in the NEW ENTRIES area of the 
controller memory. To make these changes 
active, press the RESTART key; press it 
again to confirm your choice. The controller 
will then wait until the designated time 
before starting its sampling program. 
 
Summary of Sequence: 
SET, START DELAY, ARROW(S), ENTER, #, #, #, #, ENTER, 
ARROW(S), ENTER, ARROW(S), ENTER, RESTART, RESTART. 
7.6.4.3 START DELAY using Pulse Input
The following sequence of entries are made 
on the Touchpad to create a future starting 
time for the operation of the Sampler. The 
ACTIVE SETTINGS are not being altered. 
1. Press the SET key.
2. Press the START DELAY key.
3. Press an ARROW key. Continue until 
Pulse Input is shown on the display. 
4. Press the ENTER key.
The display will show a new screen 
containing the option title PULSE INPUT 
on the top line and a 7 digit number with the 
leftmost digit flashing as an input prompt. 
To set the number of pulses required to be 
input before a sample program is started, use 
the ARROW keys to move the flashing 
prompt until it is over the digit requiring 
change. 