Campbell Scientific CVS4200 / BVS4300 Stationary Samplers User Manual

Page 64

Advertising
background image

CVS4200 / BVS4300 Stationary Samplers

1. Press the SET key.

2. Press the PROGRAM TYPE key.

3. Press an ARROW key. Continue until
Daily Cycle is shown on the display.

4. Press the ENTER key.

The display will show the response “DAILY
CYCLE Total Bottles nn“. The two digits,
nn, will flash, indicating they can be
changed . In this application, the number of
bottles must be set to 24.

Press ENTER. The second line of the
display will change to show a day of the
week. The first day that shows will be the
day the programming is being done.
Following the day of the week will be a
flashing single digit, which is the prompt for
a numeric input. Using the number keys
(0-9) enter the number of bottles to be
utilized on the first day. In this application
this will be set to 2.

Press ENTER. This will register the value
for the displayed day and change that display
to show the next day. Again, enter a number
for that particular day, remembering that in
this application this will be set to 2. If no
change in the displayed value is required, the
value has been changed or the value is zero,
pressing ENTER will advance the day of the
week. Therefore...

Press ENTER. Repeat the above procedures
until all the required containers, on their
respective days, have been allocated, or the
7 days of the week are all selected. If all 7
days have been selected, then continuous
sampling will occur for up to 12 days.

56

Advertising