6 programming program type, 1 program type overview, Programming program type – Campbell Scientific CVS4200 / BVS4300 Stationary Samplers User Manual
Page 59: Program type overview
CVS4200 / BVS4300 Stationary Samplers
The display will echo the last entry with 
<ENTERED>. 
The controller has now been given a new 
value for SAMPLE INITIATION. The new 
value resides in the NEW ENTRIES area of 
the controller memory. To make this change 
active, press the RESTART key; press it 
again to confirm your choice. The controller 
will then wait until a contact closure has 
been received before taking a sample. 
 
Summary of Sequence: 
SET, SAMPLE INITIATION, ARROW(S), ENTER, RESTART, 
RESTART. 
7.6.6 Programming PROGRAM TYPE
7.6.6.1 PROGRAM TYPE Overview
PROGRAM TYPE is the function that determines how the sampler will 
perform its program. A variety of options are available. These options are 
programmable from the Touchpad and require only that the sampler have the 
correct equipment configuration to utilize them. The basic function of the 
PROGRAM TYPE is to determine the movement of the distributor. 
The program option which determines that 
all the samples that are gathered will be 
placed in a single container. The sampler 
program terminates after the specified 
number of samples have been taken. 
This option is used for discrete sampling 
applications, to deposit one or a number of 
samples to one container before advancing 
to the next container. The interval betwee
samples is controlled by the SAMPLE 
INITIATION function. The 
multi-composite setting is programmable up 
to 99 samples per container, for up to 24 
containers depending on the hardware 
configuration. 
n