;Call instruction 188 to set the ports as outputs
;with the outputs set low.
2: SDM-IO16 (P188)
1: 00

SDM

Address

2: 90

Command

Code

Option

;configure the ports

3: 0000

Ports

16-13

;Set all ports as output and low

4: 0000

Ports

12-9

5: 0000

Ports

8-5

6: 0000

Ports

4-1

7: 27

Return Code Loc [ ErrCount ] ;for return code

8: 10

First Loc [ Heat_1 ]

;for control values

9: 1.0

Mult

10: 0.0

Offset


;Set flag 1 high to indicate we have run the setup code
3: Do (P86)
1: 11

Set Flag 1 High


4: End (P95)

;of IF block


;Measure the five temperatures, with 5 107 probes in this example
5: Temp (107) (P11)
1: 5

Reps

2: 1

SE

Channel

3: 1

Excite all reps w/E1

4: 1

Loc [ Temp_1 ]

5: 1.0

Mult

6: 0.0

Offset


6: Beginning of Loop (P87)

;Master loop: end

1: 0

Delay

;loop at step 30

2: 5

Loop

Count


;Start heater control logic
7: If (X<=>F) (P89)

;if temperature is below

1: 1

-- X Loc [ Temp_1 ]

;heater threshold

2: 4

<

3: 23.5

F

4: 30

Then

Do

;then


8: Z=F (P30)

;put a '1' into heater control

1: 1

F

;location

2: 0

Exponent

of

10

3: 10

-- Z Loc [ Heat_1 ]


9: End (P95)

;end 'then do'


10: If (X<=>F) (P89)

;if the heater is on (heater

1: 10

-- X Loc [ Heat_1 ]

;control location <>0)

2: 2

<>

3: 0

F

4: 30

Then

Do

;then

20