23: End (P95)

;end 'then do'


24: Else (P94)

;else, if cooler is off


25: Z=F (P30)

;put a '0' into cooler

1: 0

F

;control location

2: 0

Exponent

of

10

3: 15

-- Z Loc [ Cool_1 ]


26: End (P95)

;end 'then do/else'


;End cooler control logic
;Start fan control logic based on heater/cooler
27: If (X<=>F) (P89)

;if heater is on

1: 10

-- X Loc [ Heat_1 ]

2: 2

<>

3: 0

F

4: 11

Set Flag 1 High

;set flag 1


28: If (X<=>F) (P89)

;if cooler is on

1: 15

-- X Loc [ Cool_1 ]

2: 2

<>

3: 0

F

4: 11

Set Flag 1 High

;set flag 1


29: If Flag/Port (P91)

;if flag 1 is set

1: 11

Do if Flag 1 is High

2: 30

Then

Do

;then


30: Z=F (P30)

;put a '1' into fan control

1: 1

F

;location

2: 0

Exponent

of

10

3: 20

-- Z Loc [ Fan_1 ]


31: Else (P94)

;else, if flag 1 is reset


32: Z=F (P30)

;put a '0' into fan control

1: 0

F

;location

2: 0

Exponent

of

10

3: 20

-- Z Loc [ Fan_1 ]


33: End (P95)

;end 'then do/else'


34: Do (P86)

;reset flag 1

1: 21

Set Flag 1 Low


35: End (P95)

;end master loop


;End fan control logic based on heater/cooler
;Start fan control logic based on time

22