Operation – Blodgett SB-G Series User Manual

Page 13

Advertising
background image

OM-G-SB 11

Operation

A. Controls

Operating controls are located on the front panel of the unit.

1. The on/off switch starts the unit or shuts it off.

2. The RESET indicator lights to show that the boiler has filled with water and

that the main burners can ignite.

3. The start switch (momentary) lights the main burners. It also restarts the

unit if electrical power is interrupted, or if a low water condition in the

boiler disables the unit.

4. In addition to operating these controls, there are gas supply controls

located on the gas valve.

When the control knob is “ON,” gas flows to the pilot, as well as to the main

burners.

Timers are located on the front right side of the unit. There are two timers —

one each for the upper and lower cavities.

The timer is used in two ways:

5. Turning the timer to any setting delivers steam to the cavity until the timer

runs down to OFF. At that time a red LED switches on and a beeper sounds

and the steam flow to the compartment stops.

6. When turned all the way to the ON position, the timer allows continuous

steaming. A green LED is turned on, and the timer does not time down.

Steam continues until the timer knob is turned to the OFF position.

WARNING

ALL POTENTIAL USERS OF THE EQUIPMENT

SHOULD BE TRAINED IN SAFE AND CORRECT

OPERATING PROCEDURES.