Troubleshooting – Blodgett SB-G Series User Manual

Page 23

Advertising
background image

OM-G-SB 21

Troubleshooting

SYMPTOM

WHO

WHAT TO CHECK

Timer control will not operate.

User

a. Is the electrical supply turned on?

b. Is the ON/OFF switch in the base cabinet turned on?

c. Is boiler started? Is the green light in the ON/OFF switch lit?

d. Are any fuses blown?

No steam to cavities.

User

a. Has steam pressure developed?

b. Is steam supply turned on?

c. Is the door closed? (Doors must be closed before steam will

enter the cavity).

Door leaking steam or water.

User

a. Are the drain holes at the rear of the cavity blocked?

b. Does the door gasket need replacement?

c. Is the door latch in need of adjustment?

(See the Maintenance section).

d. Is the unit level?

Excessive steam coming from

the vent pipe.

User

a. Is the water supply turned on?

b. Is the condenser hose kinked or obstructed?

c. Is the condenser spray solenoid working?