4

OM-G-SB

The G-SB Steamer is designed to bring you years of service. It has two stainless steel

cavities (cooking chambers) and a control compartment, which houses the electrical

components and steam valves. In each cavity, a powerful blower circulates the steam

for increased heating efficiency. Each cavity, depending on model, will hold either

three or five steam table pans (12” x 20” x 2-1/2”).

A 16 gauge stainless steel case encloses the cavities and the control compartment

that house electrical components. The door hinges are reversible (the doors may be

hung to open from the left or right).

Operator Controls are located on the front panel.

The steamer cavities are mounted on a cabinet base containing a gas-fired steam

boiler that generates low pressure steam. This model uses a spark ignition system.

The boiler is small enough to fit in a 24-1/8” wide by 34-3/16” deep by 29-3/16” tall

(maximum) cabinet. The boiler is constructed of 1/4” thick steel, which is certified by

the American Society of Mechanical Engineers (ASME) for pressure vessels. All welds

are hydrostatically tested. The boiler is also equipped with required instruments,

fittings, and controls per CSD-1 (Controls and Safety Devices for automatically fired

boilers). Heat transfer fins inside the combustion chamber add to the unit’s high

efficiency. The unit is rated as 60% efficient or better, with a firing rate of 200,000 BTU

per hour using natural or propane gas. Energy output is 120,000 BTU per hour, with an

effective boiler horsepower of 3.7.

The drain system includes a spray condenser, which suppresses any steam escaping

from the chamber and cools condensate water going into the drain.

Equipment Description

WARNING

THE UNIT MUST BE INSTALLED BY

PERSONNEL WHO ARE QUALIFIED TO WORK

WITH ELECTRICITY AND/OR GAS, AND

PLUMBING. IMPROPER INSTALLATION CAN

CAUSE INJURY TO PERSONNEL AND/OR

DAMAGE TO THE EQUIPMENT. THE UNIT

MUST BE INSTALLED IN ACCORDANCE WITH

ALL APPLICABLE CODES.

G-SB steamers have two steam

compartments with individual controls

mounted on a gas-fired boiler base.

Advertising