Boiler Cleaning

WARNING

WATER AND VALVES MAY BE VERY HOT,

AND MAY CAUSE BURNS. PROTECT HANDS

FROM HOT SURFACES AND WATER.

Whenever the boiler is turned off and allowed to cool to about 130ºF, it drains

automatically. This should be done every day to minimize scale buildup inside the

boiler.

In addition to this draining, however, the following cleaning procedure should be

followed using a regular schedule. This will prevent the accumulation of lime on the

water level probes and interior surfaces of the boiler. The actual time between these

scheduled cleanings depends on the water quality and hours of operation. Minimally,

We recommend cleaning the boiler at least once each month.

A. Suggested Tools

a.

1/2” hardened square wrench extension

b. Pipe Joint compound (approved for 300ºF steam)

c. Delimer Descaler

d. Spray Degreaser

e. Nylon pad(s)

B. Procedure

1. Turn the boiler on/off switch to the OFF position.

2. Slowly open the manual drain valve to empty the boiler. The valve is located

under the boiler.

3. Close the manual drain valve.

4. Turn off water supply to the boiler.

5. Allow the boiler to cool. This takes several hours, so it is recommended that

you cool the boiler overnight.

6. Turn on/off switch to “ON” to close the automatic drain valve.

7. Using a 1/2” hardened square wrench extension, remove one of the 1” NPT

pipe plugs from the front of the boiler.

8. Pour 32 ounces of de-limer into the boiler.

9. Replace the pipe plug. Use pipe joint compound, and tighten the plug

securely.

10. Turn on water supply to allow water to fill the boiler.

11. When the reset light appears, press the START switch.

12. Allow boiler pressure to develop. Let it stand for approximately 15 minutes

after pressure has built up. A badly limed unit may require more than 15

minutes.

The manual drain valve is

located under the boiler.

WARNING

USE SAFETY GLASSES AND RUBBER

GLOVES AS RECOMMENDED BY DE-LIMING

AGENT MANUFACTURER.

CAUTION

DO NOT USE A CLEANING OR DE-LIMING
AGENT THAT CONTAINS SULFAMIC ACID

OR ANY CHLORIDES, INCLUDING

HYDROCHLORIC ACID (HCL). IF THE

CHLORIDE CONTENT OF ANY PRODUCT IS

UNCLEAR, CONSULT THE MANUFACTURER.

Advertising