background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

23

510975

Figure 13

D816I

1

3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)

4

Metallic or Non-Metallic Sheathed Cable
(Copper Wire Only)

5

Pigtail to Dryer (Refer to NOTE above)

2

30 Ampere Fuses or Circuit Breaker

6

Neutral

3

Neutral Wire

7

Terminal Block in Dryer

NOTE: The power cord (pigtail) is NOT supplied with
the electric dryer. Type of pigtail and gauge of wire
must conform to local codes and instructions.

The method of wiring the dryer is optional and subject
to local code requirements.

NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.

1

3

5

6

7

4

2

PIGTAIL CONNECTION

DIRECT CONNECTION

L1

L2

L1

L2

INTERMEDIATE
SHUT-OFF BOX

(may or may not

be fused)

POWER SUPPLY

POWER SUPPLY

INTERMEDIATE

FUSE BOX (may

be omitted if

service entrance

box is fused)

WALL

RECEPTACLE

A typical

30-Amp

Three-Wire
Receptacle

NEMA Type

10-30R

120 ± 12

V.A.C.

120 ± 12

V.A.C.

240 ± 12

V.A.C.

NOTE: Use COPPER WIRE only.
Shorter than 15

k (4.5 m) – use 10 A.W.G.

Longer than 15

k (4.5 m) – use 8 A.W.G.

Advertising