© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

39

510975

Figure 26

.

Figure 27

H318I

1

NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening must be
sized per local codes.

3

Clearance per Local Codes

4

No Screen or Cap

5

Clean Out Cover – Inspect Monthly

2

Wall

HORIZONTAL EXHAUST INSTALLATION

2

3

4

EXHAUST

OUTLET

1

A

B

C

D

E

F

G

H

I

J

K

AIR

FLOW

EXHAUST AIR FLOW

MAXIMUM LENGTH OF

DUCT 30 feet (9.1 m)

30°

5

H319I

1

Roof

2

Wall

3

2" (5 cm) Minimum

4

NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, an opening must
be sized as shown or per local codes.

1

2

3

4

VERTICAL EXHAUST INSTALLATION

CONNECT TO DRYER

Duct Station

Minimum Diameter of

Collector Duct

A

4 inches (10.2 cm)

B

8 inches (20.3 cm)

C

9 inches (22.9 cm)

D

10 inches (25.4 cm)

E

11 inches (27.9 cm)

F

12 inches (30.5 cm)

G

13 inches (32.6 cm)

H

14 inches (35.6 cm)

I

15 inches (38.1 cm)

J

15 inches (38.1 cm)

K

16 inches (40.6 cm)

To reduce the risk of fire and the
accumulation of combustion gases, DO
NOT exhaust dryer air into a window well,
gas vent, chimney or enclosed,
unventilated area, such as an attic, wall,
ceiling, crawl space under a building or
concealed space of a building.

W045

WARNING