Installation

33

510975

Location Requirements

Select a location with a solid floor. Dryers installed in
residential garages must be elevated 18 inches (46 cm)
above the floor.

No other fuel burning appliance should be installed in
the same closet with the dryer unit.

The dryer unit must not be installed or stored in an
area where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the dryer unit
with a 1/4" driver. All four legs must rest firmly on the
floor so the weight of the dryer is evenly distributed.
The dryer unit must not rock.

IMPORTANT: Unless completely assembled, DO
NOT slide the dryer unit across the floor. DO NOT
slide the unit once the leveling legs have been
extended, as the legs and the base could become
damaged.

The dryer unit needs sufficient clearance and an
adequate air supply for proper operation and
ventilation, and for easier installation and servicing.
(Minimum clearances are shown in Figure 21).

Figure 21

D358I

NOTE: Shaded areas indicate adjacent structure.

A

D

C

B

E

A

E

Dryer and Exhaust Duct Clearances

Area

Description

Minimum Clearance

A

Dryer Sides

0

"

(0 cm)

B

Dryer Top (Rear 24

"

)

12

"

(30.5 cm)

C

Dryer Rear

4

"

(10.2 cm)

D

Dryer Top (Front 4

"

)

0.5

"

(1.3 cm)

E

Exhaust Duct from Combustible Construction

2

"

(5.1 cm)