Installation

510975

34

Dryer Exhaust Requirements

Exhaust System Materials

Exhaust system materials are not supplied with the
dryer unit.

Exhaust duct must be four inches (10.2 cm) in
diameter having no obstructions. Rigid metal duct is
recommended. Non-combustible flexible metal duct is
acceptable. Do not use plastic or thin foil ducting,
because it contributes to poor drying performance and
collects lint, which can lead to a fire hazard.

Never install flexible duct in concealed spaces, such as
a wall or ceiling.

DO NOT use sheet metal screws on exhaust pipe joints
or other fastening means which extend into the duct
that could catch lint and reduce the efficiency of the
exhaust system. Secure all duct joints with duct tape or
pop-rivets.

NOTE: Kits described above are optional exhaust
system materials available at extra cost.

.

Figure 22

A clothes dryer produces combustible
lint. To reduce the risk of fire and
combustion gas accumulation the dryer
MUST be exhausted to the outdoors.

W116

This gas appliance contains or produces
a chemical or chemicals which can cause
death or serious illness and which are
known to the State of California to cause
cancer, birth defects, or other
reproductive harm. To reduce the risk
from substances in the fuel or from fuel
combustion, make sure this appliance is
installed, operated, and maintained
according to the instructions in this
manual.

W115

To reduce the risk of fire and the
accumulation of combustion gases, DO
NOT exhaust dryer air into a window well,
gas vent, chimney or enclosed,
unventilated area, such as an attic, wall,
ceiling, crawl space under a building or
concealed space of a building.

W045

To reduce the risk of fire, DO NOT use
plastic or thin foil ducting to exhaust the
dryer.

W354

WARNING

Description

Kit P/N

May Be

Obtained

Locally

Exhaust Duct (4" Dia.)

Not Available

Yes

Flexible Metal Duct
(4" Dia.)

521P3

Yes

Weather Hoods, with
hinged dampers (4")

Not Available

Yes

Directional Exhaust
Kit

528P3

No

Tape

Not Available

Yes

DO

DON’T

D354I

D356I