Make-Up Air Requirements

It is important that the laundry room has adequate
make-up air for the dryer(s). A dryer exhausts 220 cfm
(measured at back of the dryer) and sufficient make-up
air must be supplied to replace the air exhaust by the
dryer.

Make-Up Air Dos and Don’ts

Do

Supply adequate air for ventilating air, drying air
and gas dryer combustion air.

NOTE: Each dryer pocket must have 40 square
inches (260 cm

2

) of unobstructed flow of make-up

air for proper operation.

Energy efficient buildings with low air
infiltration rates should be equipped with an air
exchanger that can accommodate on demand
make-up air needs in the laundry room. These
devices can be obtained through your building
contractor or building material suppliers.

Don’t

Draw make-up air from a room containing a gas
fired water heater.

Draw make-up air from a room containing a dry
cleaner or a hair salon.

Exhaust Direction

The dryer unit can be exhausted to the outdoors
through the back, left, right or bottom of the dryer unit.
EXCEPTION: Gas dryers cannot be vented out the
left side because of the burner housing.

Dryer unit is shipped from factory ready for rear
exhaust; no kits required.

Exhausting the dryer through sides or bottom (lower
dryer only) can be accomplished by installing a
Directional Exhaust Kit 528P3 available as optional
equipment at extra cost.

.

Figure 23

D701I

1

Weather Hood with Hinged Dampers

2

Rigid or Flexible Metal Duct

1

53256 DIRECTIONAL EXHAUST KIT

2