Option 10 - show list of authorized groups, Option 11 - set telnet timeout in seconds, Option 12 - display telnet timeout in seconds – AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 109

Advertising
background image

NetLinx Security with a Terminal Connection

103

NetLinx Integrated Controllers

Option 10 - Show List of Authorized Groups

1.

Type 10 and <ENTER> at the Security Setup prompt (at the bottom of the Main Security

Menu) to display a list of all authorized group accounts. A sample session response is:

The following groups are currently enrolled:

administrator

Group 1

Press <ENTER> key to continue

2.

Press <ENTER> to return to the Security Setup Menu.

Option 11 - Set Telnet Timeout in seconds

This feature is disabled after the installation of firmware build 130 or higher onto your target

Master.

1.

Type 11 and <ENTER> at the Security Setup prompt (at the bottom of the Main Security

Menu) to set the Telnet Timeout value, in seconds. A sample session response is:

Specify Telnet Timeout in seconds:

2.

Enter the number of seconds before you want The Telnet session to timeout, and press

<ENTER> to return to the Security Setup Menu.

Option 12 - Display Telnet Timeout in seconds

This feature is disabled after the installation of firmware build 130 or higher onto your target

Master.

1.

Type 12 and <ENTER> at the Security Setup prompt (at the bottom of the Main Security

Menu) to view the current Telnet Timeout value (in seconds). A sample session response is:

Telnet Timeout is 10 seconds.

2.

Press <ENTER> to return to the Security Setup Menu.

Option 13 - Make changes permanent by saving to flash

When changes are made to the security settings of the Master, they are initially only changed in

RAM and are not automatically saved permanently into flash. This selection saved the current

security settings into flash. Also, if you attempt to exit the Main Security Menu and the security

settings have changed but not made permanent, you will be prompted to save the settings at that

time.

Type 13 and <ENTER> at the Security Setup prompt to (permanently) save all changes to flash.

Changes made to the target Master from within the Terminal window are not reflected
within the web browser, until the Master is rebooted and the web browser connection
is refreshed.
Any changes made to the Master, from within the web browser are instantly reflected
within the Terminal session without the need to reboot.