AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 58

Advertising
background image

Configuration and Firmware Update

52

NetLinx Integrated Controllers

13. Right-click the associated System number and select Refresh System. This establishes a new

connection to the specified System and populates the list with devices on that system. The

communication method is then highlighted in green on the bottom of the NetLinx Studio

window.

14. Cycle power to the Integrated Controller (unplug and reconnect power to the unit).

FIG. 34 Select Control Card firmware file for download page (via IP)

Selected Control Card

Description field for selected KIT file

System Number and Device Number
must match the System and Device values
listed in the Workspace window

Firmware download
status

Firmware file

The OUTPUT and INPUT LEDs alternately blink to indicate the Master is
incorporating the new firmware. Allow the Master 20 - 30 seconds to reboot and
incorporate the new firmware.

This process of cycling power acts to reset the updated NetLinx Control Card and
detect its new firmware update. It also serves to allow the Integrated Controller to
detect and reflect the new firmware on the card to the NetLinx Studio display on the
Workspace window.