AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 133

Advertising
background image

Troubleshooting

127

NetLinx Integrated Controllers

Troubleshooting Information (Cont.)

Symptom

Solution

During the firmware upgrade
process, NetLinx Studio failed to
install the last component.

This occurs when initially upgrading the on-board Master from a
previous firmware (build 117 or lower), to the new Web Security
firmware (build 130 or higher).

• Only upon the initial installation of the new build there will be a failure

of the last component to successfully download. This is part of the
initial update procedure and will not occur during uploads of later
firmware.

• After the last components fails to install, click Close and reboot the

on-board Master by selecting Tools > Reboot the Master
Controller
> Continue to continue the process.

• After the last components fails to install, click Close and reboot the

Master by selecting Tools > Reboot the Master Controller > Continue
to begin the process.

• Refer to the Upgrading the On-board Master Firmware via an

IP section on page 46 for detailed procedures.