Closing and securing the integrated controller – AMX NetLinx Integrated Controllers NI-3000 User Manual

Page 39

Advertising
background image

Installation and Upgrading

33

NetLinx Integrated Controllers

6.

Insert the upgrade card into the connector opening with the arrow facing towards the pins, then

push it in firmly until the contact pins are completely inside the flash card and securely

attached to the connector (FIG. 21).

7.

To complete the upgrade process, close and re-secure the Integrated Controller enclosure using

the procedures outlined in the following section.

Closing and Securing the Integrated Controller

Once the card has been replaced, close and re-secure the outer housing:

1.

Align the cover over the unit and gently slide-down the cover until the chassis housing

openings are aligned over their respective openings along both the sides and top of the unit.

2.

Begin pushing-down the housing until the cover is securely positioned over circuit board.

3.

Insert the chassis housing screws into their respective locations, as shown in FIG. 20.

4.

Securely tighten these screws by using a grounded screwdriver turning in a clockwise

direction.

5.

Re-install all connectors and apply power.

FIG. 21 Removing the Compact Flash card

Under-side groove

located below

Insert with arrow

facing towards

the connector pins

Card Removal Grooves

Any new internal card upgrade is detected by the Controller only after power is
cycled.

Advertising
This manual is related to the following products: