Additional settings
(DEGAUSS/CANCEL MOIRE)

You can manually degauss (demagnetize) the screen, and cancel
the moire.

1

Press the center of the control button.

The main MENU appears on the screen.

2

Move the control button

m

/

M

to highlight

DEGAUSS/CANCEL MOIRE and press the center of
the control button again.

The DEGAUSS/CANCEL MOIRE menu appears on the
screen.

3

Move the control button

m

/

M

to select the desired

adjustment item.

Adjust the selected item according to the following
instructions.

Degaussing the screen

The monitor is automatically demagnetized when the power is
turned on.

To manually degauss the monitor, first move the
control button

m

/

M

to select

(DEGAUSS). Then move

the control button

,

.

The screen is degaussed for about 5 seconds. If a second degauss
cycle is needed, allow a minimum interval of 20 minutes for the
best result.

Cancelling the moire

*

If elliptical or wavy patterns appear on the screen, adjust the
moire cancellation level.

To adjust the amount of moire cancellation, first move
the control button

m

/

M

to select

(CANCEL MOIRE).

Then move the control button

<

/

,

until the moire

effect is at a minimum.

* Moire is a type of natural interference which produces soft, wavy lines

on your screen. It may appear due to interference between the pattern
of the picture on the screen and the phosphor pitch pattern of the
monitor.

Resetting the adjustments (RESET)

This monitor has the following two reset methods. Use the
RESET menu to reset the adjustments.

1

Press the center of the control button.

The main MENU appears on the screen.

2

Move the control button

m

/

M

to highlight

0

RESET

and press the center fo the control button again.

The RESET menu appears on the screen.
Reset the settings according to the following instructions.

Resetting all of the adjustment data for the
current input signal (MODE)

Move the control button

<

.

The MODE item is selected. All of the adjustment data for the
current input signal is reset.
Note that the following items are not reset by this method.
• on-screen menu language (page 8)
• picture’s rotation (page 11)

Resetting all of the adjustment data to factory
preset levels (ALL)

Move the control button

,

.

The ALL item is selected. All of the adjustment data for the
current input signal is reset. All of the adjustment data (except for
the USER settings in the COLOR menu) is reset to the factory
preset levels.

Note

The monitor

s buttons will not operate for about 5 seconds when ALL is

selected.

MENU

Example of moire

01US01COV-UC.book Page 12 Monday, June 14, 1999 2:40 PM