Connecting with a digital camera or other external device

Symptom

Check

Cause/Solutions

The PictBridge
mark does not
appear on the LCD
screen of the
digital camera.

• Is the digital camera

connected correctly?

c Connect the cable correctly.

• Is the 1 (on/standby) button

turned on?

c Turn on the printer using the 1 (on/

standby) button.

• Does your digital camera

support PictBridge?

c Refer to the manual supplied with your

camera, or consult the manufacturer.

• Is “Connecting” displayed

on the printer LCD screen?

c The message is not displayed while the

printer is in the Edit, CreativePrint, or
other menu modes. Exit the menu and
then connect the cable again.

c Disconnect the digital camera and the

printer and then connect them again. Or
turn off and then on the printer and the
digital camera.

• Is the USB setting of your

camera in PictBridge mode?

c Set the USB setting of your camera to the

PictBridge mode.

You connect and
disconnect the
USB cable, but
nothing happens.

c The printer has developed an over-current

error. Unplug the AC power cord of the
printer, plug it in again, and then press the
1 (on/standby) button to recover from the
error.

You cannot stop
printing even if
you pressed
CANCEL.

c The next print from the one currently

printed will be canceled.

c Depending on the digital camera you use,

you cannot cancel printing from the
printer. Operate the digital camera to stop
printing. Refer to the operating
instructions of the digital camera.

You cannot make
index printing.

• Is the message “Could not

create printing data for some
images.” displayed?

c The printer cannot print index print of the

DPOF printing. To make index printing,
insert the memory card directly or use an
external device (

.page 16, 48).