Installation

F232062

Before any deviation from specified
installation procedures is attempted,
the customer or installer should contact
the distributor.

Increasing the drain hose length, installing
elbows, or causing bends will decrease drain
flow rates and increase drain times, impairing
machine performance.

See the Cabinet Hardmount Drain Information
table in this subsection for capacity-specific
drain information.

Installation of additional machines will require
proportionately larger drain connections. See
the Cabinet Hardmount Drain Line Sizing
table in this subsection.

Cabinet Hardmount

Drain Information

18

25

27

35

50

80

Drain connection size, ID, in (mm)

2 (52)

2 (52)

2 (52)

2 (52)

3 (76)

3 (76)

Number of drain outlets

1

1

1

1

1

1

Drain flow capacity, gal-min (l-min)

20 (76)

25 (95)

25 (95)

35 (132)

50 (189)

50 (189)

Recommended drain pit size, ft

3

(l)

1.80 (51)

2.36 (66.8)

2.50 (70.3)

3.14 (88.9)

4.52 (128)

5.90 (169)

Cabinet Hardmount

Drain Line Sizing

Minimum Drain I.D. [in (mm)]

Model

Number Of Machines

1

2

3

4

5

18

2 (51)

3 (76)

3 (76)

4 (102)

4 (102)

25

2 (51)

3 (76)

3 (76)

4 (102)

4 (102)

27

2 (51)

3 (76)

3 (76)

4 (102)

4 (102)

35

3 (76)

3 (76)

3-1/2 (89)

4 (102)

4 (102)

50

3 (76)

4 (102)

6 (152)

6 (152)

6 (152)

80

4 (102)

6 (152)

6 (152)

8 (203)

8 ( 203)