Maintenance – Alliance Laundry Systems HC35 User Manual

Page 63

Advertising
background image

61

Maintenance

F232062

b. Pump the grease gun slowly, permitting

only the following number of strokes:

Bearing grease fitting, 2 strokes

Seal grease fitting, 1 stroke

Do not pump the grease gun until
grease comes out of the bearing
housing. This can result in
overlubrication, causing damage
to bearings and seals.

Figure 49

2. Use the following procedures to determine

if V belt(s) require replacement or
adjustment. Call a qualified service
technician in either case.

a. Check V belt(s) for uneven wear and

frayed edges.

b. For groove-pulley drive systems, verify

alignment by placing a straightedge
across both pulley faces. The
straightedge should make contact with
the pulleys in four places. See
Figure 50.

Figure 50

H047IE3A

Seal Grease Fitting

Bearing Grease Fitting

H040IE1A

Motor

Motor

Pulley

Basket

Pulley

Straight

Edge