Installation – Alliance Laundry Systems HC35 User Manual
Page 53
![background image](/manuals/45320/53/background.png)
51
Installation
F232062
If the machine fails to operate after power is
connected, disconnect power and check the
control circuit fuse. Unlock and raise the top
cover. For mechanical timer, P-computer, and
S-computer models, the control circuit fuse is
on the center brace. For EDC and V-computer
models, dual control circuit fuses (1 primary
and 1 secondary) are in the control module. A
decal identifies the fuse (or fuses) in each case,
and provides the fuse rating appropriate to that
specific model.
If the control circuit fuse has blown, replace
with a fuse of the appropriate rating as
identified by the decal. Call a qualified
electrician if the replacement fuse blows.
Cabinet Hardmount
Electrical Specifications
80-Pound Capacity Models
Voltage Designation
Standard
Electric Heat
Code
Vo
lt
a
g
e
Cyc
le
P
h
ase
Wi
re
Full Loa
d
Am
p
s
Cir
c
uit
Br
eake
r
AW
G
mm
2
Full Loa
d
Am
p
s
Cir
c
uit
Br
eake
r
AW
G
mm
2
3-Speed Models
A
208-240
60
3
4
15
40
6
16
90
100
1
45
C
380-415
50
3
4
9
20
12
4
41
45
6
16
D
220-240
50
3
3
14
40
6
16
89
90
2
35
F
440-480
60
3
3
9
20
12
4
46
50
6
16
O
208-240
60
3
3
15
40
6
16
90
100
1
45
W
380-415
50
3
3
9
20
12
4
41
45
6
16
Variable-Speed Models
F
440-480
60
3
3
4.49
15
14
2.50
N/A
O
208-240
60
3
3
12.4
20
12
4
87.46
90
2
35
Note: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.