Maintenance

64

F232062

Monthly

(Continued)

5. Clean inlet hose filter screens:

a. Turn water off and allow valve to cool,

if necessary.

b. Unscrew inlet hose and remove

filter screen.

c. Clean with soapy water and reinstall.

Replace if worn or damaged.

6. Tighten motor mounting bolt locknuts and

bearing bolt locknuts, if necessary.

7. Use compressed air to clean lint

from motor.

8. Clean interior of machine, both basket and

shell, by wiping with a water-soaked
sponge or cloth.

9. Use compressed air to ensure that all

electrical components are free of moisture
and dust.

10. For variable-speed models only, clean

AC drive cooling fan blades monthly
(more often if required by the condition of
the air).

a. Open the top cover and remove the

control module cover.

b. Gently wipe the fan blades clean with a

dry cloth.

Quarterly

Note: Disconnect power to the machine
before performing the quarterly maintenance
procedures.

1. Tighten door hinges and fasteners,

if necessary.

2. Tighten anchor bolts, if necessary.

3. Verify that the drain motor shield is in

place and secure.

4. Check all painted surfaces for bare metal.

(Matching gray paint is available from the
manufacturer.)

If bare metal is showing, paint with

primer or solvent-based paint.

If rust appears, remove it with

sandpaper or by chemical means.
Then paint with primer or solvent-
based paint.

5. Clean steam filter, where applicable. See

Figure 52.

a. Turn off steam supply and allow time

for the valve to cool.

b. Unscrew cap.

c. Remove element and clean.

d. Replace element and cap.

Figure 52

H042IE1A

Cap

Filter

Element

Advertising