17

Preventive Maintenance

Your system requires minimal, routine preventive maintenance. As such, the following

should be done on a routine basis to ensure that your system remains reliable:

Daily

Clean the liquid level sensors. These sensors are located on the side walls of the wash and

sanitizer tanks. They are the white plastic discs with metal centers. Clean the sensor faces

thoroughly. If cleaned regularly, a washcloth and soapy water are all that is required.


If the liquid level sensors are not cleaned regularly, the machine

may fail to operate; or it may be possible to run it without water,

which may cause serious damage to the unit.

Monthly


IMPORTANT: Turn off the power to the unit at the main breaker

prior to performing the following task!

Clean the pump motor fan shroud with a damp, soapy rag. The motor shroud is the

"vented" cover located at the end of the motor (closest to the control panel). This will

prevent grease and dust from accumulating in the cover's openings, which can obstruct the

airflow that cools the motor.

De-lime the wash sink. Simply add a de-liming agent to a sink of warm, fresh water and

run the system overnight.

Ask your chemical sales representative to recommend a specific de-liming agent.

There are no other preventive maintenance procedures that you will need to perform on

your

Power Soak

system. You need not be concerned about greasing the motor bearings, as

they are permanently sealed. If you have any questions regarding the preventive

maintenance procedures, please contact the factory at

800-444-9624.