32

Component Operation and Checks

Programming the

Watlow

Heat Controller

21. Press the “down” arrow. The display will read "P,d”. It may also flash “LO” or

“hI”. Push and hold the “set” button. The display should read “no”. If not, adjust

by pushing the “up” or “down” arrow. Release the “set” button.

22. Press the “down” arrow. The display will read "Pb h”. It may also flash “LO” or

“hI”. Push and hold the “set” button. The display should read “0”. If not, adjust by

pushing the “down” arrow. Release the “set” button.

23. Press the “down” arrow. The display will read "hY5h”. It may also flash “LO” or

“hI”. Push and hold the “set” button. The display should read “2”. If not, adjust by

pushing the “down” arrow. Release the “set” button.

24. Press the “down” arrow. The display will read "CAL”. It may also flash “LO” or

“hI”. Push and hold the “set” button. The display should read the number

determined in step 17. If not, adjust by pushing the “down” arrow

**

. Release the

“set” button.

25. Push "up" and "down" arrows simultaneously for 5 seconds. The display will read

the actual temperature. It may also flash “LO” or “hI”. Release the “up” and

“down” arrows.

26. Push "up" and "down" arrows simultaneously for 5 seconds. The display will read

“AUT”. It may also flash “LO” or “hI”. Release the “up” and “down” arrows.

Push the “down” arrow repeatedly until the display reads "CnF9”.

27. Push and hold the “set” button. The display will read “no”. Change to “YES” by

pushing the “up” arrow. Release the “set” button.

28. The display will read “In”. Push the “up” arrow.

29. The display will read "tA9”. Push and hold the “set” button. The display will go

blank. Push the “down” arrow. The display will read “PCOA”. Release the “set”

button.

30. Push "up" and "down" arrows simultaneously for 5 seconds. The display will read

the actual temperature. It may also flash “LO” or “hI”. Release the “up” and

“down” arrows.

The Watlow heat control is now programmed.

**

If a thermometer was not available for step 17, use zero.