Component Operation and Checks

Programming the

Watlow

Heat Controller

1. Push "up" and "down" arrows simultaneously for 5 seconds. The display should

read "CnF9”. If not, push the “down” arrow repeatedly until it does.

2. Push and hold the “set” button. The display will read “no”. Change to “YES” by

pushing the “up” arrow. Release the “set” button.

3. The display should read "tA9”. If not, push the “up” arrow repeatedly until it does.

Push and hold the “set” button. Push the “up” arrow repeatedly until the screen goes

blank. Release the “set” button.

4. Press the “down” arrow. The display will read "In”. Push and hold the “set”

button. The display should read “J”. If not, adjust by pushing the “up” arrow.

Release the “set” button.

5. Press the “down” arrow. The display will read "C_F”. Push and hold the “set”

button. The display should read “oF”. If not, adjust by pushing the “up” arrow.

Release the “set” button.

6. Press the “down” arrow. The display will read "rL”. Push and hold the “set”

button. The display should read “114”. If not, adjust by pushing the “up” or

“down” arrow

. Release the “set” button.

7. Press the “down” arrow. The display will read "rh”. Push and hold the “set”

button. The display should read “118”. If not, adjust by pushing the “up” or

“down” arrow. Release the “set” button. Return to step 6 if necessary.

8. Press the “down” arrow. The display will read "Ot1”. Push and hold the “set”

button. The display should read “ALM”. If not, adjust by pushing the “up” arrow.

Release the “set” button.

9. Press the “down” arrow. The display will read "Ot2”. Push and hold the “set”

button. The display should read “hEAt”. If not, adjust by pushing the “up” arrow.

Release the “set” button.

10. Press the “down” arrow. The display will read "dl5P”. Push and hold the “set”

button. The display should read “Ac”. If not, adjust by pushing the “up” arrow.

Release the “set” button.

11. Press the “down” arrow. The display will read "ALtY”. Push and hold the “set”

button. The display should read “Prno”. If not, adjust by pushing the “up” arrow.

Release the “set” button.

If the display will not go to 114, perform step 7 first, then return to step 6.

Advertising