33

Component Operation and Checks

RKC

Heater Controller

The set temperature will be shown in the red illuminated display on the top right corner.

The actual temperature will be shown in the green illuminated display in the center. The

set temperature will then start blinking. You then push the "arrow up" or "arrow down"

button to the temperature setting you would like. When finished, press the “set” button

again. The range of adjustment is typically 114 to 120 degrees.

The

RKC heat control is pre-programmed. There is no programming required.

There are three messages that may show up different than above:

• “uuuu” – This means that the current temperature of the water is below the

operating range (114°F-120°F). This is normal after filling the sink with water

below 114°F, and the heat contactor is pulled in (heating). If the heat contactor is

not pulled in, there is a problem. See troubleshooting guide.

• “oooo” – This means that the current temperature of the water is above the

operating range (114°F-120°F). This is normal after filling the sink with water

above 120°F, and the heat contactor is not pulled in (not heating). If the heat

contactor is pulled in, there is a problem. See troubleshooting guide.

• “Err” – If this happens, call the Metcraft service department at 800-944-0404.

The

RKC heat control pins are marked, but may be difficult to identify. The following

diagram maps the pin locations. Note the three gold pins as reference: