Start-up procedure – Hawk Industries Hawkjaw Jr. Manual 65K-ALS Serial Numbers 4 to 9 User Manual

Page 14

Advertising
background image

Start-up Procedure

1. Connect the air power source with the Air

(A) line.

2. Make sure the hydraulic reservoir is full.
3. Connect the hydraulic Pressure (P), Tank

(T) and Air (A) lines. "P" and "T" Port
Designations are stamped on the Main
Hydraulic Manifold (M).

4. Check for hydraulic leaks. If leaks occur,

see Trouble Shooting, p. 67.

5. No motion should occur. If there is

movement of any parts on the HawkJaw,
see Trouble Shooting, p. 67-69.

Operation

14

NOTE

Tightly connect the hose fittings. A

loose connection causes a pressure drop

in the hydraulic fluid which heats up the

fluid and reduces component life.

Part Numbers

Part Name

Part #

Male Quick Disconnect (P)

061-H52

Female Quick Disconnect (T) 061-H53
Male Air Quick Disc. (A)

061-A12M

Female Air Quick Disc.

061-A12F

A

M

P

T