Setting Make Up Torque

Operation

K

S

T

TN

Shown set for 30,000 ft. lbs.

RNA

RN

G

22

Operation

1. Follow the steps on pages 14-21.
2. Use the Red needle adjust (RNA)

to rotate the Torque gauge red
needle
(RN) to the desired
torque
.

3. Rotate the Torque Set knob (K)

counter- clockwise as far as the
Torque Set knob (K) will turn.

4. Press and hold Spin (S) until the

stand rotates down to the
shoulder.

5. Release Spin (S).
6. Push in the wrench Grip (G).
7. Press and hold Torque (T). While

holding down Torque (T), rotate
the Torque Set knob (K) clock-
wise
.

8. When the Torque gauge needle

(TN) reaches the desired torque,
stop rotating the Torque Set knob
(K).

9. Release Torque (T). Immediately

release the wrench Grip (G).

10. The Hawkjaw torque is now set

and can now be removed from the
pipe.