Transportation and Storage

Receive the unit

1. Inspect the package for damaged or missing items upon delivery.
2. Note any damaged or missing items on the receipt and freight bill.
3. File a claim with the shipping company if anything is out of order.

Unpack the unit

1. Remove packing materials from the unit.

Dispose of all packing materials in accordance with local regulations.

2. Inspect the unit to determine if any parts have been damaged or are missing.
3. Contact your ITT representative if anything is out of order.

Pump handling

WARNING:

• Make sure that the pump cannot roll or fall over and injure people or damage property.
• These pumps might use carbon or ceramic silicon carbide components. Do not drop the pump or

subject it to shock loads as this can damage the internal ceramic components.

NOTICE: Use a forklift truck or an overhead crane with sufficient capacity to move the pallet with the
pump unit on top. Failure to do so can result in equipment damage.

Lifting methods

WARNING:

• Assembled units and their components are heavy. Failure to properly lift and support this equipment

can result in serious physical injury and/or equipment damage. Lift equipment only at the specifically
identified lifting points. Lifting devices such as eyebolts, slings, and spreaders must be rated, selected,
and used for the entire load being lifted.

• Crush hazard. The unit and the components can be heavy. Use proper lifting methods and wear steel-

toed shoes at all times.

• Do not attach sling ropes to shaft ends.

Use the supplied lifting lugs and suitable slings in order to lift the entire pump to a vertical position and
lower the unit into the sump. Then use the lifting lugs on the motor and a suitable sling in order to hoist
the motor into position. Use a tag line attached to the casing end in order to prevent the pump from swinging.