Check

Explanation/comment

Checked

If the pump handles corrosive

fluids, make sure that the piping

allows you to flush out the liquid

before you remove the pump.

If the pump handles liquids at

elevated temperatures, make sure

that the expansion loops and

joints are properly installed.

This helps to prevent misalignment due to linear

expansion of the piping.

Make sure that all piping

components, valves and fittings,

and pump branches are clean

prior to assembly.

Make sure that the isolation and

check valves are installed in the

discharge line.

Locate the check valve between the isolation valve and

the pump. This will permit inspection of the check valve.

The isolation valve is required for regulation of flow, and

for inspection and maintenance of the pump. The check

valve prevents pump or seal damage due to reverse flow

through the pump when the driver is turned off.

Use cushioning devices.

This protects the pump from surges and water hammer

if quick-closing valves are installed in the system.

Alignment criteria for pump flanges

Type

Criteria

Axial

The flange gasket thickness is ±0.03 in. (0.8 mm).

Parallel

Align the flange to be within 0.001 in./in. to 0.03 in./in. (0.025 mm/mm to 0.8 mm/mm) of

the flange diameter.

Concentric You can easily install the flange bolts by hand.

Suction piping for optional dry pit, outside tank mount, and tailpipe
applications

Checklist

Check

Explanation/comment

Checked

Install an elbow at the pump.

Whenever possible, perform these actions:

• Use long radius elbows.
• Move the elbow further from the suction.
• Eliminate unneeded elbows.

Make sure the suction piping is a larger

diameter than the pump suction.

Install separate suction lines when more

than one pump is operating from the same

source of supply.

Make sure that the suction piping contains

no air pockets.

Make sure that the suction piping slopes

upwards toward the pump.

Make sure that all joints are air tight.

Provide a method to prime the pump.

For outside tank mount and dry pit applications,

allow the fluid level inside the tank or pit to rise

above the casing level.
In tailpipe applications, submerge the casing

before you start the pump.