Disassemble the column – Goulds Pumps 3171 - IOM User Manual

Page 44

Advertising
background image

Disassemble the column

1. Remove the column down to the steady bearing housing bolts (372B).

If your pump has no intermediate steady bearings (only one column section), then skip this step since
you do not have any column extension (306) or steady bearing housing (213).
a) Start at the casing end of the pump and remove the column extensions (306), steady bearing

housings (213), and deflectors (123) one at a time. Support the shaft in order to prevent bending
while you remove these sections.
It is not necessary to remove the head column (192). Do not remove the steady bearings at this
time. Refer to inspection procedures prior to removal.

192

213

369

357X

306

536E

197

123

372B

2. Remove the pump half coupling hub (233) and key.
3. Remove the locking bolts (370C) and then slide bearing shell (134) assembly with the shaft out

through the motor support (240).

CAUTION:
Two people should handle any shaft over 9 feet long. Improper handling can bend the shaft.

136

382

112

370C 193B 134

369A

332A 361A

370D

415

113 333 400

122

M/MT/L Only

4. Use a screwdriver in order to pry the labyrinth seal (332A) from the bearing shell (134).

NOTICE:
We recommend that you replace the labyrinth seal every time the pump is inspected.

5. Remove the bearing retaining ring (361A).

Maintenance (Continued)

42

Model 3171 Installation, Operation, and Maintenance Manual