Disassemble the column
1. Remove the column down to the steady bearing housing bolts (372B).
If your pump has no intermediate steady bearings (only one column section), then skip this step since
you do not have any column extension (306) or steady bearing housing (213).
a) Start at the casing end of the pump and remove the column extensions (306), steady bearing
housings (213), and deflectors (123) one at a time. Support the shaft in order to prevent bending
while you remove these sections.
It is not necessary to remove the head column (192). Do not remove the steady bearings at this
time. Refer to inspection procedures prior to removal.
192
213
369
357X
306
536E
197
123
372B
2. Remove the pump half coupling hub (233) and key.
3. Remove the locking bolts (370C) and then slide bearing shell (134) assembly with the shaft out
through the motor support (240).
CAUTION:
Two people should handle any shaft over 9 feet long. Improper handling can bend the shaft.
136
382
112
370C 193B 134
369A
332A 361A
370D
415
113 333 400
122
M/MT/L Only
4. Use a screwdriver in order to pry the labyrinth seal (332A) from the bearing shell (134).
NOTICE:
We recommend that you replace the labyrinth seal every time the pump is inspected.
5. Remove the bearing retaining ring (361A).