6. Slide the bearing shell (134) off the bearing and shaft.
7. Remove the locknut (136) and the lockwasher (382).
8. Use a suitable bearing puller in order to remove the bearing (112).

Make sure to save the bearing for inspection.

9. Set the shaft on a table where it is adequately supported.

You do not need to disassemble the pump any further unless you need to replace bad parts.

Preassembly inspections

Replacement guidelines

Casing check and replacement

Inspect the casing for cracks and excessive wear or pitting. Thoroughly clean gasket surfaces and alignment
fits in order to remove rust and debris.
Repair or replace the casing if you notice any of these conditions:

• Localized wear or grooving that is greater than 1/8 in. (3.2 mm) deep
• Pitting that is greater than 1/8 in. (3.2 mm) deep
• Irregularities in the casing-gasket seat surface

Impeller replacement

This table shows the criteria for replacing the impeller parts:

Impeller parts

When to replace

Vane edges

When you see cracks, pitting, or corrosion damage

Gaskets, O-rings, and seats replacement

• Replace all gaskets and O-rings at each overhaul and disassembly.
• Inspect the seats. They must be smooth and free of physical defects.

In order to repair worn seats, skin cut them in a lathe while you maintain dimensional relationships
with other surfaces.

• Replace parts if the seats are defective.

Column sections

Inspect the column section(s) (306, 192) for any cracks or excessive corrosion damage. Replace if necessary.

Motor support

Inspect the motor support (240) for any cracks or excessive corrosion damage. Replace if necessary.

Shaft replacement guidelines

Shaft measurement check

Check the bearing fits of the shaft. If any are outside the tolerances shown in the Bearing fits and
tolerances table, then replace the shaft.

Shaft straightness check

Check the shaft straightness. Use “V” blocks or balance rollers to support the shaft on the bearing fit
areas. Replace the shaft if runout exceeds 0.001 in. (0.03 mm).

NOTICE:
Do not use shaft centers for the runout check as they may have been damaged during the removal of the
bearings or impeller.

Maintenance (Continued)

Model 3171 Installation, Operation, and Maintenance Manual

43

Advertising