• Located in accordance with the dimensions given in the example drawing
• Enough space inside the pipe sleeves to allow the final position of the foundation bolts to align with

the holes in the sub-base flange

1

2

3

4

5

6

1.

Hex nut

2.

Washer

3.

Support plate

4.

0.5 in. (12.5 mm) anchor bolt

5.

Anchor bolt sleeve

6.

Foundation (by customer)

Figure 3: Example of a typical installation

Support plate installation

Install the support plate with a pit cover

If access to the bottom of the pit cover is not possible during the installation process, you must assemble
and install the pump (without the motor), support plate, and pit cover as a unit. You must install the pit
cover perfectly level in order to make sure that the pump remains straight up and down when installed.
The vapor-proof option includes machined, gasketed fits between the support plate/pit cover and the pit
cover/foundation. You must install these gaskets in order to ensure emissions performance. Bolt the pit
cover to a metal sole plate with a machined surface in order to ensure an air tight seal.
1. Carefully lower the pit cover onto the foundation bolts.
2. Use as long a level as possible in order to level the pit cover in all directions with shims or wedges.
3. Hand tighten the anchor bolts. Check the level and re-shim if necessary.
4. Tighten all anchor bolts in a star pattern in order to avoid distorting the pit cover.
5. If access to the bottom side is possible, carefully lower the pump and support plate onto the pit cover.
6. Install all bolts and hand tighten.
7. Check the level on the support plate and re-shim if necessary.
8. Tighten all bolts in a star pattern in order to avoid distorting the support plate.

Install the support plate without a pit cover

1. Carefully lower the pump and support plate onto the foundation bolts.
2. Level the support plate in all directions using shims and wedges.
3. If you use the vapor-proof option, then perform one of these actions in order to make sure that you

have an air-tight seal:

Support plate

type

Action

Standard

Insert the supplied gasket between the two flanges. Bolt the support plate to a

metal sole plate that has a machined surface.

Installation (Continued)

18

Model 3171 Installation, Operation, and Maintenance Manual