Lubrication conversion, Frame lubrication conversion, Rame lubrication conversion – Goulds Pumps HT 3196 i-FRAME - IOM User Manual

Page 122

Advertising
background image

Description

Shaft and Bearing

Frame Assembly

Adapter Seal Chamber Impeller

Casing

Size

Model HT 3196

MTi 1–3/4 in.

Shaft Dia. Max

BHP-122 HP

3X4-7 A70
2X3-8 A60
3X4-8 A70

3X4-8G A70

1X2-10 A05
1.5X3-10 A50
2X3-10 A60
3X4-10 A70
3X4-10H A40
4X6-10 A80
4X6-10H A80

1.5X3-13 A20
2X3-13 A30
3X4-13 A40
4X6-13 A80

1x2-10LF A05

Model HT 3196

LTi 2–1/8 in.

Shaft Dia. Max

BHP-200 HP

1X2-10 A05
1.5X3-10 A50
2X3-10 A60
3X4-10 A70
3X4-10H A40
4X6-10G A80
4X6-10H A80
1.5X3-13 A20
2X3-13 A30
3X4-13 A40
4X6-13 A80

Model HT 3196

XLT-i 2–1/2 in.

Shaft Dia. Max

BHP-250 HP

6X8-13 A90
8X10-13 A100
6X8-15 A110
8X10-15 A120
8X10-15G A120

Lubrication conversion

Frame lubrication conversion

NOTICE:

• Never mix greases of different consistencies (NLGI 1 or 3 with NLGI 2) or with different thickeners.

For example, never mix a lithium-based grease with a polyurea-based grease. Doing so may result in
decreased performance.

• Remove the bearings and old grease if you need to change the grease type or consistency. Failure to

do so may result in equipment damage or decreased performance.

Use a grease that is suitable for high temperatures when you have frame pumpage temperatures greater
than 350°F (177°C). Ensure that mineral-oil greases have oxidation stabilizers and a consistency of NLGI
3.
Most pumps use Sunoco 2EP grease. High temperature units with a pumpage temperature greater than

350° F (177°C) use Mobil SCH32.
This table shows which brand of grease to use when lubricating the pump.

Table 22: Lubricating-grease requirements

Pumpage temperature less than

350°F (177°C)

Pumpage temperature greater

than 350°F (177°C)

NGLI consistency

2

3

Mobil

Mobilux EP2

SCH32

Maintenance

120

Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual