If the pump size is... Then...
XLT-i

1. Align the end plate on the pump side to the bearing housing so that

you meet these conditions:
a.

The large slots on the end plate do not touch the bearing housing
tap bolts.

b. The small slots align with the impeller adjusting bolts.

2. Fasten the end plate to the bearing housing using the jam nuts on the

impeller adjusting bolts.

3. Check the impeller clearance. Refer to the impeller clearance table for

the correct impeller clearance.

1

2

3

4

1.

Driver

2.

Pump end plate

3.

Bearing housing

4.

Jam nut

3. Put the pump-half of the coupling guard in place:

a) Slightly spread the bottom apart.
b) Place the coupling guard half over the pump-side end plate.