Part description HT 3196

3196

3796

HT 3196

CV 3196

LF 3196

3198

NM 3196

Casing

Impeller

Cover

Power end

Figure 6: HT 3196 part description

This table describes the pump casing parts.

Table 3: Casing

Part

Description

Discharge

Top-centerline

Casing ventilation

Self venting

Mounting method

Centerline-mounted to withstand misalignment and distortion from thermal piping

loads. It also maintains vertical alignment at elevated temperatures.

Standard flange

ANSI class 300 raised-face serrated flange.

Impeller

The impeller is

• fully open
• screwed onto the shaft

The threads are sealed from the pumped liquid by a graphite O-ring.

Product Description

Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual

15