Casing areas to inspect

The arrows point to the areas to inspect for wear on the casing:

100

Figure 18: 3196, HT 3196, LF 3196, NM 3196, and 3198 casing

Impeller replacement

This table shows the criteria for replacing the impeller:

Impeller parts

When to replace

Impeller vanes

• When grooved deeper than 1/16 in. (1.6 mm),

or

• When worn evenly more than 1/32 in. (0.8 mm)

Pumpout vanes

When worn or bent more than 1/32 in. (0.8 mm)

Vane edges

When you see cracks, pitting, or corrosion damage

Impeller areas to inspect

101

a

b

c

c

Figure 19: Areas to inspect for wear on the 3196 impeller.

Frame adapter check and replacement

• Replace the frame adapter if it has cracks or excessive corrosion damage.
• Make sure the gasket surface is clean.

Maintenance