Model icb, 2 shaft sealing, 3 bearing – Goulds Pumps ICB - IOM User Manual

Page 16: 4 approximate value for sound pressure level

Advertising
background image

Installation, Operation and Maintenance Instruction

Model ICB


ICB 100-English

page 7

Revision 00

Article No 21999991

Issue 05/2006

S1 - Single-mech. seal acc. DIN 24960 l1k /
EN 12756 form U
S4 - Single-mech. seal acc. DIN 24960 l1k /
EN 12756 form U
with Quench (throttle bush)

Position (5) - Material Impeller

N = Cast Iron (0.6025)

L = Ductile Iron (0.7043)

V = Carbon Steel (1.4408)

W = Duplex (1.4517)

Position (6) - Material pump casing (same coding as
impeller, cast iron not available)

Position (7) - Stub shaft

2 - without shaft sleeve (Duplex 1.4462 std)

Position (8) - IEC Motor size

3.2 Shaft Sealing

Pumps of design ICB are exclusively sealed with
single mech. seals with installation dimensions acc. to
EN 12756 (DIN 24960), design "K", form "U".
Two shaft sealing variants are available. On the data
sheet and / or the order confirmation the kind of shaft
sealing is given. An instruction for the mounting and
operation of mech. seals is contained in the particular
"Mounting Instruction of Shaft Sealing".
For nominal size (d

1

) of the mech. seal refer to

following chart.

Type

nom. size

d

1

of mech.

seal

Type

nom. size

d

1

of mech.

seal

40-25-160 33

100-65-160

43

40-25-200 33

100-65-200

43

40-25-250 43

100-65-250

43

50-32-160 33

100-65-315

53

50-32-200 33

125-80-160

43

50-32-250 43

125-80-200

43

50-32-315 43

125-80-250

43

65-40-160 33

125-80-315

53

65-40-200 33

125-100-200

43

65-40-250 43

125-100-250

53

65-40-315 43

125-100-315

53

80-50-160 33

150-125-250

53

80-50-200 33

150-125-315

53

80-50-250 43

200-150-250

53

80-50-315 43

The mech. seal used in the standard design is
not resistant to mineral oils.

For further details about mech. seals, as well as
the dangers of accidents, connected to them
refer to chapter 6.6 and chapter 7.2.

3.3 Bearing

The shaft is guided by the ball bearings of the motor.
The bearings are grease lubricated for life and,
therefore maintenance-free.



3.4 Approximate Value for Sound
Pressure Level

Sound pressure level L

pA

in dB(A)

Pump alone

Pump + Motor

Nominal
power
P

N

in kW

2950
min

-1

1450
min

-1

975

min

-1

2950
min

-1

1450
min

-1

975

min

-1

0,55 50,5 49,5 49,0 58,0 52,0 51,5
0,75 52,0 51,0 50,5 59,0 54,0 53,0

1,1 54,0 53,0 52,5 60,0 55,5 54,5
1,5 55,5 55,0 54,5 63,5 57,0 56,0
2,2 58,0 57,0 56,5 64,5 59,0 58,5
3,0 59,5 58,5 58,0 68,5 61,0 62,0
4,0 61,0 60,0 59,5 69,0 63,0 63,0
5,5 63,0 62,0 61,5 70,0 65,0 65,0
7,5 64,5 63,5 63,0 70,5 67,0 67,0

11,0 66,5 65,5 65,0 72,0 69,0 68,5
15,0 68,0 67,0 66,5 72,5 70,0 70,5
18,5 69,0 68,5 68,0 73,0 70,5 74,0
22,0 70,5 69,5 69,0 74,5 71,0 74,0
30,0 72,0 71,0 - 75,0 72,0 -
37,0

73,0 - - 76,0 - -

Sound pressure level L

pA

measured in 1 m distance

from pump surface acc. to DIN 45635, part 1 and 24.
Room and foundation influences are not considered.
The tolerance for these values is

±3 dB(A).

Addition with 60 Hz-operation:
Pump alone:

Pump with motor: +4 dB(A)

3.5 Permitted Nozzle Loads and Torques
at the Pump Nozzles ...

... following the Europump-Recommendation for
pump acc. to ISO 5199.
The data for forces and torques are only valid for
static piping loads.
All values for forces and torques refer to standard
materials EN-GJS400-18LT and 1.4408.