Model icb, Spare parts, spare pumps, 1 spare parts – Goulds Pumps ICB - IOM User Manual

Page 25: 2 stand-by pumps

Advertising
background image

Installation, Operation and Maintenance Instruction

Model ICB


ICB 100-English

page 16

Revision 00

Article No 21999991

Issue 05/2006

ƒ Remove cuttings out of the stud hole (e.g. with

compressed-air), screw in and make safe thread
pins (904.41 and 904.42) (e.g. with Omnifit 100 M
or Loctite).

ƒ Check smooth running of stub shaft opposite to

motor flange with a dial gauge. The pointer
deflection of the dial gauge must not exceed 0,1
mm.

pic 11



























Measure A by motor size

Type

80

90

100 112 132 160 180 200

40-25-160

157 157 197 197 197 232

-

-

40-25-200

157 157 197 197 197 232

-

-

40-25-250

162 162 202 202 202 237 237 237

50-32-160

157 157 197 197 197 232

-

-

50-32-200

157 157 197 197 197 232

-

-

50-32-250

162 162 202 202 202 237 237 237

50-32-315

-

-

202 202 197 237 237 237

65-40-160

157 157 197 197 197 232

-

-

65-40-200

157 157 197 197 197 232 232

-

65-40-250

162 162 202 202 202 237 237 237

65-40-315

-

-

202 202 197 237 237 237

80-50-160

157 157 197 197 197 232 232

-

80-50-200

157 157 197 197 202 232 232 232

80-50-250

-

162 202 202 202 237 237 237

80-50-315

-

-

202 202 202 237 237 237

100-65-160

162 162 202 202 202 237 237 237

100-65-200

- 162 202 202 202 237 237 237

100-65-250

- 162 202 202 206 237 237 237

100-65-315

-

- 206 206 202 241 241 241

125-80-160

- 162 202 202 202 237 237 237

125-80-200

- 162 202 202 202 237 237 237

125-80-250

-

- 202 202 202 237 237 237

125-80-315

-

-

-

206 206 241 241 241

125-100-200

-

- 202 202 202 237 237 237

125-100-250

-

- 216 216 216 251 251 251

125-100-315

- - - -

206

241 241 241

150-125-250

- - - -

216

251 251 251

150-125-315

- - - - -

241 241 241

200-150-250

- - - - -

251 251 251

9. Spare parts, Spare pumps

9.1 Spare parts

Spare parts should be selected to last for two-years
continuous operation. If no other guidelines are
applicable, we recommend that you stock the number
of parts listed below (in accordance with VDMA
24296).

To ensure optimum availability, we recommend
that suitable quantities of spare parts are held
in stock, especially if these are made from
special materials and in the case of mechanical
seals, because of the longer delivery times.

Number of pumps (incl. stand-by pumps)

2 3 4 5 6/7 8/9 10/+

Spare Parts

Number of spare parts

Impeller

1 1 1

2 2 2

20%

Wear

ring

2 2 2

3 3 4

50%

Shaft with keys and nuts

1

1

1

2

2

2

20%

Joints for pump casing
sets

4 6 8

8 9 12

150%

other joints
sets

4 6 8

8 9 10

100%

Mech. seal

sets

1 1 2

2 2 3

25%

Ordering spare parts
When ordering spare parts, please supply the
following information:

ƒ Type:

______________________________________________________________________

ƒ S/N (Order No.)

_____________________________________________________

ƒ Part

name

______________________________________________________________

ƒ Sectional

drawing

___________________________________________________

All the information is given in the data sheet and the
relevant sectional drawing.

Store spare parts in dry and clean rooms.

9.2 Stand-by pumps

It is essential that a sufficient number of stand-
by pumps are kept ready for use in plants
where failure of a pump could endanger human
life or cause damage to property or high costs.
Regular checks should be carried out to ensure
that such pumps are always ready for use (see
Point 6.8).

Advertising