Installation, Operation and Maintenance Instruction

Model ICB


ICB 100-English

page 14

Revision 00

Article No 21999991

Issue 05/2006

guard plate is bent through so much, that it can be
inserted into the lower edge of the window of the
motor lantern.

pic 8

Pull up screw driver only so far as is absolutely
necessary to insert the guard plate into the
window. If the guard plate doesn´t stick fast in
the window after installation:
Dismantle guard plate once again, flatten it and
install again.

8.4 Removal of the Back Pull Out
Assembly

The back pull out assembly consists of all pump parts
except the volute casing (102V). As the pumps are
constructed in block design, the volute casing (102V)
can remain on the foundation and in the piping, if it´s
not the volute casing itself, which must be repaired.
ƒ Drain volute casing (102V) via drain plug (912.11).
ƒ Loosen screws of existing sealing or flushing

pipings.

ƒ Loosen screws of support food (183) from the

foundation (not existing on all sizes).

ƒ Hang the Back Pull Out Assembly onto a lifting

device, so that it won´t sink down or press into the
volute casing during the dismounting. Example
see picture 9 for lifting recommendations.

pic 9

ƒ Loosen hexagen head bolt (901.11) from the

casing.

ƒ Using the jack screws provided (901.42),

separate the Back Pull Out Assembly from the
casing.

8.5 Removal of Impeller

Notice attached "Mounting Instruction for Shaft
Sealing".

ƒ If the impeller has back vanes check the axial

clearance "a" between the impeller (230) and
casing cover (161) before you continue the
dismounting. Refer to sect. 8.7.1.

ƒ Loosen impeller nut with a sensitive hit on the

wrench (right-hand thread). If necessary back up
with a pry bar in the cross boring of the stud shaft
(in clamp area).

ƒ Draw off the impeller (230) with two screw drivers

or pry bars (picture 10). Remove key (940.31).

Be sure to locate pry bars under impeller vanes
to prevent damage to the impeller.

ƒ For further dismounting, and for installation, the

Back Pull Out Assembly should be placed in a
vertical position. Prevent assembly from tipping!

pic 10

8.6 Removal of Shaft Sealing

ƒ Before you remove casing cover notice "Mounting

Instructions for Shaft Sealing".

ƒ Unfasten hexagonal nut (902.32) (not available on

all pump sizes) and take casing cover (161) out of
bearing bracket (344).

8.7 Removal of Stub Shaft

ƒ Loosen screws (920.41) and pull motor with stub

shaft (210) out of the motor lantern (341).

ƒ Loosen radial stub shaft screwing (904.41 and

904.42) (stud bolts) and deduct stub shaft (210)
from motor shaft. For support (break loose) you