background image

Installation, Operation and Maintenance Instruction

Model ICB


ICB 100-English

page 22

Revision 00

Article No 21999991

Issue 05/2006



Index of parts:
161

Casing

cover

210

Shaft

230

Impeller

412.21 O-ring
412.32 O-ring
433 Mech.

seal

471Q Quench

cover

502.31*) Wear

ring

527 a)

Fixing ring

542.31

Throttle bush

560 b)

Pin

904.31 a)

Grub screw

904.32*) Grub

screw

923 Impeller

nut

*) optional

a)

not for all designs

b)

only for mech. seals with PTFE-O-rings

Subject to techn. alterations!

Nominal

size of

mech. seal

∅d

1

∅d

7

l

1K

A

B

∅d

L

QI, Q0

33 33

48

42,5

7,5

50

19

1/4-18

NPT

43 43

61

45

7,5

52,5

28

3/8-18

NPT

53 53

73

47,5

10

57,5

38

3/8-18

NPT

3. Removal of mech. seal

For that purpose use the appropriate sectional
drawing and the enclosed data sheet of the mech.
seal.
ƒ Remove and disassemble the pump acc. to the

Installation, Operation and Maintenance
Instructions including chapter 8.6.

ƒ Remove fixing ring (527) (if existing) and rotating

part of the mech. seal (433) from shaft (210).

ƒ Refer to the enclosed data sheet of the mech.

seal, if set screws are to be loosened at the mech.
seal at first.

ƒ Remove casing cover (161) together with quench

cover (471Q). Use hexagonal screws (901.42) as
jack screws.

ƒ Pull stationary part of the mech. seal (433) and

throttle bush (542.31) out of quench cover (471Q).

ƒ Clean drilling for stationary seal ring (

∅d

7

) in the

quench cover (471Q) and surface of the shaft
(210).

.

The reuse of mech. seals, which have already
been used for a longer time, can lead to leaking
at the seal faces after reinstallation. Therefore
the replacement of the mech. seal through a
new one is recommended. The dismounted
mechanical seal can be reconditioned by the
manufacturer and serve as a replacement
mech. seal.

4. Installation of mech. seal

For that purpose use the appropriate sectional
drawing and the enclosed data sheet of the mech.
seal.

It is only allowed to install mech. seals, which
have a certificate of Conformity acc. the
Directive 94/9/EC.
On changing the mech. seal type resp. the
mech. seal manufacturer the data regarding
max. operating temperature of the pumped
medium and temperature class must be
checked again.

Pay attention to the utmost cleanness!
Especially the seal faces must be clean, dry
and undamaged. Don´t apply lubrication on the
seal faces of the mech. seal.

ƒ If a lubricant is provided with the replacement

mech. seal, you should use this.

Use mineral grease or oil only, if you are
completely sure that the elastomers of the
mech. seal are oil resistant. Use no silicone.

Use only lubricants when you are sure that
there can´t occur any dangerous reactions
between the pumpage and the lubricant.

Make all required parts available, so that
assembly can be completed quickly. The
lubricants are only effective for a short time.
After that the axial movability and, thus, the
automatic adjustment of the elastomeres is lost.

Don´t push elastomers over sharp edges. If
necessary use mounting devices.

ƒ Put throttle bush (542.31) into quench cover

(471Q) carefully.

ƒ Press the stationary part of the mech. seal in the

quench cover (471Q). For this you can eventually
use a stamp with a soft surface. Unequal load can
lead to cracking of the seal face.

ƒ Don´t damage seal face!
ƒ Pay attention that the stationary ring is in solid

contact with the quench cover. The seal face must
be installed perpendicular to the shaft.

ƒ If a pin (560) is existing, be careful that it fits into

the slot of the mech. sealing, without touching the
mech. seal.

ƒ Insert casing cover (161) carefully, until it fits

axially in the bearing frame lantern (344).

ƒ Push the rotating unit of the mech. seal on the

shaft (210).

Advertising