Printing the configuration label, Figure 15 – configuration print sample – AMT Datasouth 400 User Manual

Page 25

Advertising
background image

User's Guide 25

Printing the Configuration Label

1. Ensure the printer is powered off.

2. Verify that the media is properly loaded and routed as detailed in Loading Media

Section.

3. While pressing and holding the FEED key, power on the printer.

4. The READY LED (right most LED) will blink twice.

5. Continue holding the FEED key while the media feeds for several label lengths.

6. When the printer begins to print the configuration label you may release the FEED key.

Note: Media width at least 3 inches wide should be used for the configuration print out. The

following figure is an example configuration printout. The feature settings on your
printer may vary based on any setup changes made or firmware version installed in the
printer.

Figure 15 – Configuration Print Sample

Media Type

Thermal Transfer

Media Sensing

Gap

Sensor Threshold

70

Media Length

4.00 Inches

Media Width

4.00 Inches

Present Distance

+0.24 Inches

Present Sensor

Disabled

Vert Print Align

0.00 Inches

Horz Print Align

+0.20 Inches

Vert Size Adjust

0

Print Darkness

-8

Print Speed

6

Interface Select

Auto Select

COM1: Baud Rate

9600

COM1: Parity

None

COM1: Data Bits

8

COM1: Handshake

RTS & XON

COM1: PAL Xmit

Disabled

Emulation Mode

PAL Emulation

Date

Not Installed

Time

Not Installed

Daylight Saving

Disabled

Firmware Rev.

110156 A

PAL Boot Drive

Auto Detect

Max Media Length

12.00 Inches

Keypad Lockout

Disabled

Label Count

582

Drive A: (131072)

Empty

Drive B: (262144)

Empty

Drive C: (0)

Empty

Drive D: (32768)

Empty

Advertising