Parallel (centronics) interface, Auto interface select – AMT Datasouth 400 User Manual

Page 71

Advertising
background image

User's Guide 71

Parallel (Centronics) Interface

The parallel port uses a standard 36-pin Centronics connector.

Pin

Direction

Definition

Pin

Direction

Definition

1

In

/STROBE

13

Out

SELECT

2

In

Data 1

14,15

NC

3

In

Data 2

16

-

Ground

4

In

Data 3

17

-

Ground

5

In

Data 4

18

NC

6

In

Data 5

19 to 30 -

Ground

7

In

Data 6

31

NC

8

In

Data 7

32

Out

/Fault

9

In

Data 8

33 to 36 -

NC

10

Out

/ACK

11

Out

BUSY

12

Out

PE

Auto Interface Select

The setup feature Interface Select controls the operation of interface arbitration. One of 3 settings is possible:

Parallel Only: With this setting the serial interface is ignored.

Serial Only: With this setting the parallel interface is ignored.

Auto Select: With this setting, the printer automatically arbitrates between the parallel and serial interfaces. The first
interface to go active maintains active status while the other interface is held busy. After a time out period, the other
interface is placed in a ready state.

Advertising