RMS Technologies R356-RO CONTROLLER/DRIVER User Manual
Page 18

This will set the controller to 1.4 Amps Peak. How did we get 1.4 Amps? 1.0
Amps x 1.4 = 1.4 A Peak.
WARNING!: Setting the Current to a value greater than the Motor’s rated
current will damage your motor, and may overheat the controller.
Connecting Multiple R356 Units
Connect multiple units by using the Converter card, shown below. If using the
RS232-to-RS485 converter card, daisy chain all four wires: power, ground, RS485+
and RS485- prior to plugging into the converter card.
Figure 7: Connection using RS232 Converter Card
If using the USB485 converter card, connect all the power and ground lines on the
units to the main power supply. Then daisy chain the RS485+ and RS485- lines
prior to plugging into the USB485 card.
R356 Controller & Driver
Page 18
Version 1.01
RMS Technologies
4/3/2009