Half- stepping current wave form – RMS Technologies R356-RO CONTROLLER/DRIVER User Manual

Page 25

Advertising
background image

The position versus time graph just above, plots only the A Phase, following the eight
different steps the motor will make. Current is changing with each position. Recall

that a negative in electronics simply means reverse direction of current flow.

Take a look at position #7. If we were to draw the arrow
at position 7 as the hypotenuse of a triangle, it would

look like the triangle to our left. Recall from geometry a
90°-45°-45° triangle is a 1-1-√2 combination. The √2,

or 1.4 value is also the radius of the dotted circle shown
above. Therefore, during certain steps, Phases A or B will

receive 1.4 Amps of current. But the average, or RMS
current throughout these 8 steps is only 1.0 Amps. RMS

and Amps/Phase is the same meaning.

The 1.4A along this hypotenuse is also known as the 2-Phase On position, since both A and

B Phases are “On” and receive current. It is also known as the peak current.

As we see the waveform that’s plotted for the A Phase, the highest value on the curve is
known as the peak value.

Motors have a rated current, or average RMS value since in operation, the current is

continuously changing. The most logical way to describe a rating is to take an average, or
RMS (root means squared) value. But drivers understand current in terms of peak current,

therefore the conversion is: Amps/Phase x 1.4 = Amps Peak

R356 Controller & Driver

Page 25

Version 1.01

RMS Technologies

4/3/2009

1

3

7

5

1

2

3

4

100%

100%

0%

HALF- STEPPING

Current Wave Form

PHASE A

Current

POSITION

PHASE B

PHASE A

2

4

8

6

5

6

7

8

141%

141%

time

Peak current
(1.4 times Amps/Ph)

Average, or RMS
Is only 1 Amp/Ph

1.41 AMP

1 AMP

1 AMP

(√2)